7 recalls

Equipment

Feb 8, 2011 · NHTSA campaign 11V082000 · 10,683 vehicles

Problem: Tiffin motorhomes is recalling certain recreational vehicles equipped with 1200-SERIES norcold refrigerators. The population of refrigerators being addressed contains either a sensing algorithm or thermal switch to shut off power to the refrigerator when high temperatures are detected in order to prevent a potential fire. The response times of the sensor algorithm and thermal switch devices to stop power are not sufficient.

Original NHTSA wording

TIFFIN MOTORHOMES IS RECALLING CERTAIN RECREATIONAL VEHICLES EQUIPPED WITH 1200-SERIES NORCOLD REFRIGERATORS. THE POPULATION OF REFRIGERATORS BEING ADDRESSED CONTAINS EITHER A SENSING ALGORITHM OR THERMAL SWITCH TO SHUT OFF POWER TO THE REFRIGERATOR WHEN HIGH TEMPERATURES ARE DETECTED IN ORDER TO PREVENT A POTENTIAL FIRE. THE RESPONSE TIMES OF THE SENSOR ALGORITHM AND THERMAL SWITCH DEVICES TO STOP POWER ARE NOT SUFFICIENT.

Risk: The sensing algorithm or thermal switch installed to shut off power to the refrigerator when high temperatures are detected due to a possible hydrogen gas leak May not shut off in sufficient time to prevent a fire.

Original NHTSA wording

THE SENSING ALGORITHM OR THERMAL SWITCH INSTALLED TO SHUT OFF POWER TO THE REFRIGERATOR WHEN HIGH TEMPERATURES ARE DETECTED DUE TO A POSSIBLE HYDROGEN GAS LEAK MAY NOT SHUT OFF IN SUFFICIENT TIME TO PREVENT A FIRE.

Remedy & notes

Tiffin motorhomes is working with norcold to identify and notify any affected owners. Owners will be instructed to contact norcold dealers to receive the remedy free of charge. Please see norcold's defect report 10E-049 for additional information. The safety recall began on February 17, 2011. Owners May contact norcold at 1-800-767-9101.

Owners May also contact the national highway traffic safety administration's vehicle safety hotline at 1-888-327-4236 (tty 1-800-424-9153), or go to <a href=http://www.safercar.gov>http://www.safercar.gov</a> .

Equipment

Nov 22, 2010 · NHTSA campaign 10V585000 · 2,717 vehicles

Problem: Tiffin is recalling certain recreational vehicles equipped with 1200-SERIES norcold refrigerators. The population of refrigerators being addressed contains either a sensing algorithm or thermal switch to shut off power to the refrigerator when high temperatures are detected in order to prevent a potential fire. The response times of the sensor algorithm and thermal switch devices to stop power are not sufficient.

Original NHTSA wording

TIFFIN IS RECALLING CERTAIN RECREATIONAL VEHICLES EQUIPPED WITH 1200-SERIES NORCOLD REFRIGERATORS. THE POPULATION OF REFRIGERATORS BEING ADDRESSED CONTAINS EITHER A SENSING ALGORITHM OR THERMAL SWITCH TO SHUT OFF POWER TO THE REFRIGERATOR WHEN HIGH TEMPERATURES ARE DETECTED IN ORDER TO PREVENT A POTENTIAL FIRE. THE RESPONSE TIMES OF THE SENSOR ALGORITHM AND THERMAL SWITCH DEVICES TO STOP POWER ARE NOT SUFFICIENT.

Risk: The sensing algorithm or thermal switch installed to shut off power to the refrigerator when high temperatures are detected due to a possible hydrogen gas leak May not shut off in sufficient time to prevent a fire.

Original NHTSA wording

THE SENSING ALGORITHM OR THERMAL SWITCH INSTALLED TO SHUT OFF POWER TO THE REFRIGERATOR WHEN HIGH TEMPERATURES ARE DETECTED DUE TO A POSSIBLE HYDROGEN GAS LEAK MAY NOT SHUT OFF IN SUFFICIENT TIME TO PREVENT A FIRE.

Remedy & notes

Tiffin is working with norcold to identify and notify any affected owners. Owners will be instructed to contact norcold dealers to receive the remedy free of charge. Please see norcold's defect report 10E-049 for additional information. The recall began on February 17, 2011. Owners May contact norcold at 1-800-767-9101 or Tiffin at 1-256-356-8661.

Owners May also contact the national highway traffic safety administration's vehicle safety hotline at 1-888-327-4236 (tty 1-800-424-9153), or go to <a href=http://www.safercar.gov>http://www.safercar.gov</a> .

Equipment

Nov 17, 2009 · NHTSA campaign 09V443000 · 528 vehicles

Problem: Tiffin is recalling certain recreational vehicle equipped with norcold model 1200LR and 1200LRIM refrigerators, manufactured from December 1, 2001, with serial numbers between 1273701 and 1536607, non-consecutively. A fatigue failure in the section of the cooling unit which contains the refrigerant could allow the liquid solution to slowly leak. If a leak occurs and the refrigerator continues to be operated after solution circulation has ceased the heat source could generate very high temperatures. At such high temperatures, the cooling unit could rupture.

Original NHTSA wording

TIFFIN IS RECALLING CERTAIN RECREATIONAL VEHICLE EQUIPPED WITH NORCOLD MODEL 1200LR AND 1200LRIM REFRIGERATORS, MANUFACTURED FROM DECEMBER 1, 2001, WITH SERIAL NUMBERS BETWEEN 1273701 AND 1536607, NON-CONSECUTIVELY. A FATIGUE FAILURE IN THE SECTION OF THE COOLING UNIT WHICH CONTAINS THE REFRIGERANT COULD ALLOW THE LIQUID SOLUTION TO SLOWLY LEAK. IF A LEAK OCCURS AND THE REFRIGERATOR CONTINUES TO BE OPERATED AFTER SOLUTION CIRCULATION HAS CEASED THE HEAT SOURCE COULD GENERATE VERY HIGH TEMPERATURES. AT SUCH HIGH TEMPERATURES, THE COOLING UNIT COULD RUPTURE.

Risk: If a leak occurs and the unit is continues to operate, hydrogen gas May be expelled and can be ignited, resulting in a fire, possibly causing serious injury or death.

Original NHTSA wording

IF A LEAK OCCURS AND THE UNIT IS CONTINUES TO OPERATE, HYDROGEN GAS MAY BE EXPELLED AND CAN BE IGNITED, RESULTING IN A FIRE, POSSIBLY CAUSING SERIOUS INJURY OR DEATH.

Remedy & notes

Tiffin is working with norcold and Tiffin will notify owners and the vehicle's refrigerator will be repaired free of charge by norcold. Please see norcold's defect report 09E-027. Owners May contact norcold's recall center at 1-800-767-9101.

Owners May also contact the national highway traffic safety administration's vehicle safety hotline at 1-888-327-4236 (tty 1-800-424-9153), or go to <a href=http://www.safercar.gov>http://www.safercar.gov</a> .

Service Brakes

Apr 3, 2009 · NHTSA campaign 09V110000 · 48,876 vehicles

Problem: Navistar is recalling certain model year my 2001-2008 Workhorse W20, W21 and W22 chassis and certain model year 2009 through 2011 monaco RV admiral, arista, monarch, and riptide recreational vehicles equipped with axles that include Bosch zops or zoht pin slide hydraulic disc brakes. When combined with occasional or seasonal vehicle operation May experience calipers sticking in the applied position. This can result in abnormal heat generation at the wheel end causing brake drag. The driver would normally have warning of the brake drag if undetected by the driver.

Original NHTSA wording

NAVISTAR IS RECALLING CERTAIN MODEL YEAR MY 2001-2008 WORKHORSE W20, W21 AND W22 CHASSIS AND CERTAIN MODEL YEAR 2009 THROUGH 2011 MONACO RV ADMIRAL, ARISTA, MONARCH, AND RIPTIDE RECREATIONAL VEHICLES EQUIPPED WITH AXLES THAT INCLUDE BOSCH ZOPS OR ZOHT PIN SLIDE HYDRAULIC DISC BRAKES. WHEN COMBINED WITH OCCASIONAL OR SEASONAL VEHICLE OPERATION MAY EXPERIENCE CALIPERS STICKING IN THE APPLIED POSITION. THIS CAN RESULT IN ABNORMAL HEAT GENERATION AT THE WHEEL END CAUSING BRAKE DRAG. THE DRIVER WOULD NORMALLY HAVE WARNING OF THE BRAKE DRAG IF UNDETECTED BY THE DRIVER.

Risk: The temperature increase at the wheel end can eventually lead to soft pedal conditions due to brake fluid boil, and possible extended stopping distance increasing the risk of a crash.

Original NHTSA wording

THE TEMPERATURE INCREASE AT THE WHEEL END CAN EVENTUALLY LEAD TO SOFT PEDAL CONDITIONS DUE TO BRAKE FLUID BOIL, AND POSSIBLE EXTENDED STOPPING DISTANCE INCREASING THE RISK OF A CRASH.

Remedy & notes

Workhorse dealers will replace all four Bosch brake caliper assemblies free of charge. The safety recall began on September 16, 2010. Owners May contact Workhorse at 1-877-246-7731.

Workhorse recall no. 50901-C and 51101-C.owners May also contact the national highway traffic safety administration's vehicle safety hotline at 1-888-327-4236 (tty 1-800-424-9153), or go to <a href=http://www.safercar.gov>http://www.safercar.gov</a> .

Equipment

Nov 5, 2007 · NHTSA campaign 07V517000 · 11,438 vehicles

Problem: On certain motor homes equipped with a two-door refrigerator manufactured by the dometic corporation, these refrigerators May have a defect in the boiler tube. Pressurized coolant solution could be released into an area where an ignition source (gas flame) is present.

Original NHTSA wording

ON CERTAIN MOTOR HOMES EQUIPPED WITH A TWO-DOOR REFRIGERATOR MANUFACTURED BY THE DOMETIC CORPORATION, THESE REFRIGERATORS MAY HAVE A DEFECT IN THE BOILER TUBE. PRESSURIZED COOLANT SOLUTION COULD BE RELEASED INTO AN AREA WHERE AN IGNITION SOURCE (GAS FLAME) IS PRESENT.

Risk: Release of coolant under certain conditions could ignite and result in a fire.

Original NHTSA wording

RELEASE OF COOLANT UNDER CERTAIN CONDITIONS COULD IGNITE AND RESULT IN A FIRE.

Remedy & notes

Tiffin motorhomes will be working with dometic in order to repair these refrigerators (please see 06E076). Dometic will repair these refrigerators by installing a secondary burn housing, a thermal fuse, and a melt fuse free of charge. Dometic has retained stericycle INC. To manage this campaign. Stericycle will assist the owner in locating dealerships or service centers and will provide assistance with scheduling of appointments. Owners May contact dometic/stericycle at 1-888-446-5157 or Tiffin at 1-256-356-8661.

Customers May contact the national highway traffic safety administration's vehicle safety hotline at 1-888-327-4236 (tty: 1-800-424-9153); or go to http://www.safercar.gov.

Electrical System

Apr 28, 2006 · NHTSA campaign 06V142000 · 1,594 vehicles

Problem: Certain motor homes built on Workhorse chassis and equipped with actia corporate instrument clusters fail to comply with the requirements of federal motor vehicle safety standard no. 101, controls and displays, and no. 105, hydraulic and electric brake systems. If the brake fail input falls below a voltage of 1.5V, the brake failure lamp and alarm will be activated. Also activation of the ABS telltale when the ABS is not properly functioning does not always occur.

Original NHTSA wording

CERTAIN MOTOR HOMES BUILT ON WORKHORSE CHASSIS AND EQUIPPED WITH ACTIA CORPORATE INSTRUMENT CLUSTERS FAIL TO COMPLY WITH THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 101, CONTROLS AND DISPLAYS, AND NO. 105, HYDRAULIC AND ELECTRIC BRAKE SYSTEMS. IF THE BRAKE FAIL INPUT FALLS BELOW A VOLTAGE OF 1.5V, THE BRAKE FAILURE LAMP AND ALARM WILL BE ACTIVATED. ALSO ACTIVATION OF THE ABS TELLTALE WHEN THE ABS IS NOT PROPERLY FUNCTIONING DOES NOT ALWAYS OCCUR.

Risk: At night the instrument cluster lights May fail and the driver May not be able to see the instrument panel gauges and the brake warning light indicator which could increasing the risk of a crash.

Original NHTSA wording

AT NIGHT THE INSTRUMENT CLUSTER LIGHTS MAY FAIL AND THE DRIVER MAY NOT BE ABLE TO SEE THE INSTRUMENT PANEL GAUGES AND THE BRAKE WARNING LIGHT INDICATOR WHICH COULD INCREASING THE RISK OF A CRASH.

Remedy & notes

Tiffin is working with Workhorse to contact the owners and remedy this campaign . Workhorse will reprogram the instrument panel cluster free of charge. Owners May contact Workhorse at 1-877-246-7731 or Tiffin at 1-256-356-0205.

Customers May also contact the national highway traffic safety administration's vehicle safety hotline at 1-888-327-4236 (tty 1-800-424-9153), or go to http://www.safercar.gov.

Service Brakes

Apr 14, 2003 · NHTSA campaign 03V149000 · 1,174 vehicles

Problem: Certain motor home chassis fail to comply with the requirements of federal motor vehicle safety standard no. 105, "hydraulic and electric brake systems." the brake system warning indicator May not function as required by standard.

Original NHTSA wording

CERTAIN MOTOR HOME CHASSIS FAIL TO COMPLY WITH THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 105, "HYDRAULIC AND ELECTRIC BRAKE SYSTEMS." THE BRAKE SYSTEM WARNING INDICATOR MAY NOT FUNCTION AS REQUIRED BY STANDARD.

Risk: In some of the affected vehicles, the brake system warning indicator will not illuminate when the ignition is in the start position or for a low brake fluid condition, if the body builder relied solely upon Ford's ivm compliance statement for the brake system warning indicator.

Original NHTSA wording

IN SOME OF THE AFFECTED VEHICLES, THE BRAKE SYSTEM WARNING INDICATOR WILL NOT ILLUMINATE WHEN THE IGNITION IS IN THE START POSITION OR FOR A LOW BRAKE FLUID CONDITION, IF THE BODY BUILDER RELIED SOLELY UPON FORD'S IVM COMPLIANCE STATEMENT FOR THE BRAKE SYSTEM WARNING INDICATOR.

Remedy & notes

Dealers will repair the brake warning lamp circuit. Owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact Tiffin at 1-256-356-8661.

Customers can also contact the national highway traffic safety administration's auto safety hotline at 1-888-DASH-2-DOT (1-888-327-4236).

Recall text as published by NHTSA and the manufacturer.

What owners complain about

Owner complaints filed with NHTSA; one complaint can name several areas. Not verified by NHTSA.

Complaints by year filed

2002: 2 complaints200222003: 1 complaints20032006: 1 complaints20062008: 1 complaints20082009: 2 complaints20092010: 2 complaints20102011: 1 complaints20112019: 1 complaints20191

2003 vs. other Tiffin Allegro years

Owner complaints by model year; the darker bar is the 2003. Click a bar to switch year.

Questions

Does the 2003 Tiffin Allegro have recalls?

Yes — NHTSA lists 7 recall campaigns covering the 2003 Tiffin Allegro, the latest from Feb 8, 2011 (equipment). A recall applies to specific vehicles: enter your VIN at nhtsa.gov/recalls to see whether yours is affected and still open.

What are the most common problems with the 2003 Tiffin Allegro?

Owner complaints filed with NHTSA most often mention service brakes (6), engine (4), electrical system (1). Complaints are consumer reports and are not verified by NHTSA.